MN003286A01-E
Chapter 10: GTR 8000 Base Radio Reference
Table 66: Power Supply LEDs
Condition
Power Off
Lamp Test
Online
Impaired
Power Supply Failure
Power Supply Fan Failure
10.2
RFDS Equipment Specifications
This section provides specifications for all the RFDS equipment.
IMPORTANT: Specifications are subject to change without notice.
10.2.1
Transmit Filter Specifications (700/800 MHz)
Table 67: Transmit Filter Specifications (700/800 MHz)
Frequency range
Insertion loss
VSWR max.
Rx selectivity
Peak instantaneous power
Passive Intermodulation
Input Connector
Output Connector
Power monitor connector
Forward power range
Reverse power range
270
Fan
Off
Red
Off
Off
Off
Red
Tx Filter Spec Limit
(700/800 MHz)
764–776 MHz,
851–870 MHz
0.7 dB
1.5:1
35 dB
32000 W
–135 dBc
7/16
7/16
Dsub-9 Male
0-500 W
0-500 W
Status
Off
Green
Green
Green
Red (blinking)
Off
Off
800 MHz Typical
0.3 dB
1.12:1
40 dB
Alarm
Off
Red
Off
Red
Red
Notes
2 x 43 dBm
0-5V DC out
0-5V DC out