Figure 78: Verifying UHF Duplexer Isolation — Connecting Duplexer Cable Assembly
5.10.5.7.1

Verifying UHF Duplexer Isolation

Procedure:
1 Connect test equipment as shown in
Test Equipment on page
2 Observe and note the level in dBm as shown on the service monitor.
3 Connect the test equipment to the duplexer as shown in
Isolation — Connecting Duplexer Cable Assembly on page
4 Observe and note the level in dBm as shown on the service monitor. (If no number is displayed,
consider isolation to be greater than 105 dB, which exceeds the specification.)
5 Subtract the absolute number noted in step 4 from the number noted in step 2. The difference
should be higher than 100 dB to meet specification for isolation.
6 Repeat steps 1 through 5 for Low-Pass/High-Notch cavities with the following exceptions:
a Set service monitor for Rx or Tx frequency, whichever is higher.
b Connect service monitor to Low Pass duplexer input (cavity #1).
c Connect terminator to cavity #6.
Figure 77: Verifying UHF Duplexer Isolation — Connecting