Download Print this page

Hunter Road Force Touch GSP9700 Series Installation Instructions Manual page 29

Advertisement

3. Position the shaft portion of the outer data set arm into the safety hood shaft. Rotate the shaft of the outer
data set arm until the threaded hole aligns with the hole in the safety hood shaft. Loosely install the 3/8-16 X
1/2" socket button head cap screw (SBHCS), 74-93-2, into the hole to secure the outer data set arm.
4. Securely tighten the sensor wiring bracket with the 3/8-16 X 1/2 inch socket button head cap screw (SBHCS)
that is securing the arm to the balancer.
Tighten or loosen the 1/4-20 X 1" socket head machine screw, 75 239 2 located on the
outer data set stop support assembly, 11-1363-1-005, on the rear of the outer data set arm.
Adjust until the outer data set stop, 228-64-2 firmly cradles the hood tube.
5. Feed both the double orange banded and red/green banded sensor wires though the hole in the safety hood
shaft.
Figure 54
29