22. Install the CSMA-CBLL (This work is required only when 4 to 7 Extension consoles are expanded.)
m
. Do not touch the linear way of the transfer with bare hands during installation.
Doing so may cause rust and prevent from smooth operation of the transfer.
. The four types of the guide channel are used. The respective types of the guide channel must be in
the specified different locations.
Refer to the illustration how to identify the guide channel.
Guide channel (basic)
(1) Disconnect the connector (CN100) from the CB-117 board.
(2) Cut the 15 binding bands (14 binding bands securing the harness to the metal sheet, and 1 band
tying the 3 cables) which secure the harness.
(3) Disconnect all the harnesses from other wiring binders.
CSM-200
Guide channel (EX2)
CN100
The binding band
tying the three cables.
Guide channel (EX3)
CB-117 board
Binding bands
Guide channel (4)
4-47