Sony PetaSite CSM-200B Installation Manual page 154

Consolidated storage management system
Hide thumbs Also See for PetaSite CSM-200B:
Table of Contents

Advertisement

(2) Connecting the CSM-200 system that contains the single input power system, to the
UPS
When the shutdown function that enables status monitoring of the UPS is going to be used, connect the
UPS by either one of the following methods.
When enough capacity of the UPS can be secured, the connection using the method 1 is recommended, by
which an integrated shutdown processing can be performed.
1. Connect all the cables of PSC, DRIVE, and ROBOT to a single UPS.
UPS
and
Connect the serial interface status monitoring cable of UPS to the PSC serial interface.
For details, refer to Help on the PSC Monitoring & Maintenance Terminal of UPS.
6-4
AC inlet
for ROBOT
AC inlet
for DRIVE
UPS - AC inlet for ROBOT
UPS - AC inlet for DRIVE
UPS - PCU (redundant)
UPS - PCU (standard)
UPS - PCU
....
Power cord
....
Status monitoring cable
CSM-200