Special Commands - R&S SMCVB-K167 User Manual

Dvb-s
Table of Contents

Advertisement

®
R&S
SMCVB-K167
Parameters:
<RollOff>
Manual operation:
[:SOURce<hw>]:BB:DVBS:SYMBols <Symbolrate>
Sets the symbol rate.
Parameters:
<Symbolrate>
Manual operation:

6.4 Special Commands

[:SOURce<hw>]:BB:DVBS[:SPECial]:SETTings[:STATe]
[:SOURce<hw>]:BB:DVBS[:SPECial]:REEDsolomon
[:SOURce<hw>]:BB:DVBS[:SPECial]:SETTings[:STATe] <SpecialState>
Enables/disables special settings.
The setting allows you to switch between standard-compliant and user-defined channel
coding.
Parameters:
<SpecialState>
Manual operation:
[:SOURce<hw>]:BB:DVBS[:SPECial]:REEDsolomon <ReedSolomon>
Enables the Reed-Solomon encoder. The standard stipulates a Reed-Solomon RS
(204, 188).
Parameters:
<ReedSolomon>
Manual operation:
User Manual 1179.1058.02 ─ 02
0.20 | 0.25 | 0.35
*RST:
0.35
See
" Roll Off"
on page 23
integer
Range:
1.00E+05 to 9.00E+07
*RST:
27.5e6
See
" Symbol Rate"
on page 22
0 | 1 | OFF | ON
*RST:
0
See
"Special Settings"
0 | 1 | OFF | ON
*RST:
1
See
" Reed Solomon"
Remote-Control Commands
Special Commands
...................................................... 55
........................................................... 55
on page 24
on page 24
55

Advertisement

Table of Contents
loading