Parameters:
<SetTSPacket>
Manual operation:
[:SOURce<hw>]:BB:DVBS:PAYLoad <SetPayload>
Sets the payload area content of the transport stream packet.
Parameters:
<SetPayload>
Manual operation:
[:SOURce<hw>]:BB:DVBS:PID <SetPID>
Sets/querries the packet identifier (PID).
Set/query individual PID values for variable PID test packets or query a fixed PID value
1FFF for null PID test packets.
Parameters:
<SetPID>
Manual operation:
[:SOURce<hw>]:BB:DVBS:PIDTestpack <SetPIDTestpack>
Parameters:
<SetPIDTestpack>
Manual operation:
[:SOURce<hw>]:BB:DVBS:PRBS <SetPRBS>
Sets the period length of the PRBS generator which fills the payload area of the trans-
port stream packet (test signal or null packet).
Parameters:
<SetPRBS>
Manual operation:
User Manual 1179.1058.02 ─ 02
H184 | S187
*RST:
H184
See
" Test TS Packet"
PRBS | H00 | HFF
*RST:
PRBS
See
"Payload Test/Stuff."
integer
Range:
0 to 8191
*RST:
8191
See
"PID (Hex)"
on page 18
NULL | VARiable
*RST:
NULL
See
"PID Test Packet"
P23_1 | P15_1
*RST:
P23_1
See
"PRBS"
on page 18
Remote-Control Commands
Input Signal Commands
on page 18
on page 18
on page 18