Forced Power Down - Viavi mA-1302 Operation Manual

Axie
Table of Contents

Advertisement

Chapter 5 mA-1302/mA-1305 Control and Operation
Powering the Chassis

Forced Power Down

This section describes how to perform a "hard shut-down". This procedure should not be
used for routinely powering down the Chassis.
NOTE
A Forced Power Down should only be used in the event the Chassis is in an
unresponsive state.
How to perform a forced shut down
1
Press and hold the Chassis On/Standby Button for approximately
5 seconds. Release the On/Standby Button when the Chassis On/Standby Button
LED flashes amber.
2
If the Chassis On/Standby Button LED flashes red, press the On/Standby Button
again.
3
Wait while the Chassis completes the power down process.
4
When the Chassis completes the power down process the On/Standby Button LED
turns amber.
Page 5-4
mA-1302/mA-1305 AXIe Chassis Operation Manual
Rev. D0
April 2020