HMS Anybus Edge Reference Manual page 76

Table of Contents

Advertisement

Settings
Could not process (committed) write command: Invalid data type <data type>
The portal wrote a point's value with the indicated invalid data type.
Could not process (committed) write command: Receive queue is full
A (committed) write command received from the portal could not be processed, because
the receive queue is full.
Could not process (committed) write command: Protocol error
A protocol error occurred while processing a (committed) write command received from the
portal.
Could not process (committed) write command: Send error
An error occurred while processing a (committed) write command received from the portal.
Could not send Nak for write command
An error occurred while sending a Nak reply for a write command received by the portal.
Could not process commit command: Library not ready
The portal wrote a point's value, but the Kolibri library was not ready to process the commit
command.
Could not process commit command: Receive error
An error occurred while receiving a commit command from the portal.
Could not process commit command: Protocol error
A protocol error occurred while processing a commit command received from the portal.
Could not process commit command: Send error
A send error occurred while processing a commit command received from the portal.
Could not process cancel command: Library not ready
The portal cancelled writing a point's value, but the Kolibri library was not ready to process
the cancel command.
Could not process cancel command: Receive error
An error occurred while receiving a cancel command from the portal.
Could not process cancel command: Protocol error
A protocol error occurred while processing a cancel command received from the portal.
Could not process cancel command: Send error
A send error occurred while processing a cancel command received from the portal.
Could not process get node properties response: Invalid node type <node type>
The portal returned the indicated invalid node type with a get node properties response.
Could not process get node properties response: Invalid index <index>
The portal returned the indicated invalid index with a get node properties response.
Could not process get node properties response: Invalid path <path>
The portal returned the indicated invalid path with a get node properties response.
Could not process get node properties response: Invalid flags <hexadecimal flags>
The portal returned the indicated invalid flags with a get node properties response.