Mating Connector Assignment To Port 15X1; Enable Signal 24 Vdc (M12 X 1, Customer Side) - Bosch Rexroth CytroPac Operating Instructions Manual

Hydraulic power unit
Hide thumbs Also See for Rexroth CytroPac:
Table of Contents

Advertisement

Configurations
"Advanced" and "Premium"

7.5.4 Mating connector assignment to port 15X1:

Enable signal 24 VDC (M12 x 1, customer side)
Connect the mating connector (optionally available, refer to chapter 17.3
"Accessories") for power supply, see fig. 16, as interface to the superior machine
control system:
Pin 1: 24 VDC supply for the hydraulic power unit
Pin 2: 24 VDC output if the hydraulic power unit is ready for operation (machine-
side bridging with pin 3 without additional enable signal)
Pin 3: 24 VDC input for external enable signal: Hydraulic power unit is put into
operation
Pin 4: 0 VDC (reference ground pin 1)
Pin 5: 24 VDC input for acknowledgment of faults/errors
Pin 6: 24 VDC output for warning, e.g. filter contamination, oil level, temperature
Pin 7
24 VDC inputs for selection of up to
and
four pre-set parameter sets,
Pin 8:
see table 5, for various pressure ratings.
-15X1
1 (WH)
2 (BN)
M12x1
1
2
A-coded
-W
-EXT
External
Fig. 16: Assignment of port 15X1: Enable signal 24 VDC
3 (GN)
4 (YE)
5 (GY)
3
4
5
Bridge closed = enable internal
Bridge open = enable external
CytroPac, RE 51055-B/06.17, Bosch Rexroth AG
Assembly
39/84
6 (PK)
7 (BU)
8 (RD)
6
7
8