22/49
Assembly
Selection tables for ready-made connection cables
BA1N16
HCS03.1E-W0100
HCS03.1E-W0150
HMS01.1N-W0110
HMS01.1N-W0150
HMS01.1N-W0210
HMS01.1N-W0300
Forced ventilation
RL2-066KBB-NN-xxx,x
(RL2-066LBB-NN-xxx,x)*
Water cooling
BA1N type
BA1N16-C3BHA-AS...
BA1N16-C3BHL-AS...
6.2.3

Plug-in connector with threaded connection

Bosch Rexroth AG R911393267_Edition 01
Selection table: BA1N power cable
Controller
HCS03.1E-W0210
HCS03.1E-W0280
HCS03.1E-W0350
RL2-067KBB-NN-xxx,x
(RL2-067LBB-NN-xxx,x)*
( )*
Alternative cable 35 mm² instead of 25 mm²
Tab. 6-5:
BA1N power cable
Selection table: BA1N encoder cable
Control units V2
RG2-002ABB-NN-xxx,x
Tab. 6-6:
BA1N encoder cable
WARNING
Connect and disconnect connectors only when they are dry and de-
energized.
During operation of the system, all connectors must be securely tight‐
ened or locked.
Observe when connecting the flange sockets:
Protect the flange sockets from external force effect.
Connect the motor to ready-made connection cables.
Connect the plug-in connector with the threaded connector M58
Before connecting, please ensure properly measured ready-made connection
cables are available. The type, size and cable cross section of the plug-in
connector must be adjusted to the motor.
1. Position power connector at thread.
BA1N Kinetic Energy Buffer
RL2-563KBB-NN-xxx,x
(RL2-563LBB-NN-xxx,x)*
Extension
RG2-500ABB-NN-xxx,x
Damage to persons or property by discon‐
necting or connecting energized connectors!
Extension

Hide quick links: