Water Supply Connection - Bosch Rexroth CytroPac Operating Instructions Manual

Hydraulic power unit
Hide thumbs Also See for Rexroth CytroPac:
Table of Contents

Advertisement

7.4 Water supply connection

For motor and frequency converter cooling, the hydraulic power unit must be
connected to a cooling water supply.
Connect the lines to the intended cooling water ports, see fig. 12, pos. 1,
according to the circuit diagram.
Tighten the fittings according to manufacturer specifications.
Make sure that the cooling water supply temperature does not fall below the
dewpoint of the ambient air around the hydraulic power unit.
Observe the following requirements:
– Maximum cooling water temperature: 25 °C.
– Minimum cooling water flow: 10 l/min.
– Maximum glycol content: 30 %.
1
Fig. 12: Cooling water ports
1
Cooling water ports 2 x G1/2
Assembly
CytroPac, RE 51055-B/06.17, Bosch Rexroth AG
35/84