40/84
Assembly
Bosch Rexroth AG, CytroPac, RE 51055-B/06.17
All "Basic", "Advanced" and "Premium" configurations
The parameter set is pre-set and can be adjusted by the customer using
ConverterWorks. F1.03 = 1, see also chapter 8.3 "Parameter settings".
Table 5: Parameter sets (pin assignment of port 15X1)
Parameter set 1
F1.05
Parameter set 2
F1.06
Parameter set 3
F1.07
Parameter set 4
F1.08
7.5.5 Mini USB service interface 14X1 for frequency converter
("Advanced" and "Premium" configuration)
Reading or configuration of parameters or reading of errors can be realized via the
mini USB service interface, see fig. 17, and the ConverterWorks or IndraWorksDS
software.
-14X1
USB A
Fig. 17: Mini USB service interface
7.5.6 Multi-Ethernet interfaces
In "Premium" configuration, the hydraulic power unit can be connected to the
superior machine control system via multi-Ethernet interfaces 21X1 (pos. 15) and
21X2 (pos. 16), see fig. 18.
Interface 21X1 (network input) is always connected.
The 21X2 interface (network output) serves for connection of additional devices. If it
is not required, close the port to maintain the protection class.
Pin 7
Pin 8
0
0
0
1
1
0
1
1