7.6.1 "Basic" configuration
In "Basic" configuration, ports pos. 14, 15 and 16 are not used.
13
14
4.1
4.2
5
Fig. 19: "Basic" configuration electrical connections
To connect the power supply, proceed as follows.
▶
Connect the filter contamination sensors, see fig. 19, pos. 4.1 and 4.2, and the
filling level and temperature sensors, see fig. 19, pos. 5, (customer side).
▶
Connect the connector plug for the enable interface (15X1) with the superior
machine control system via port pos. 12.
▶
Connect the connector plug for the feed-in/voltage supply (12X1) to port pos. 11.