7.6 Electrical interface connection

High electrical voltage!
Danger to life, risk of injury, damage to property!
Make sure that any work at the electrical equipment is only carried out by
specialized electrician.
For any work at the electric operating equipment, only use suitable insulated
tools (German Social Accident Insurance DGUV regulation 3).
Before assembling the hydraulic power unit, de-energize all relevant system
components. Observe the five safety rules (according to DIN VDE 0105-100).
Make sure that only suitable fuses are used.
After establishing the feed-in connection and prior to switching on the
protective grounding conductor connection to the power unit, particularly
check the central plate (verification by means of test records according to
DIN EN 60204-1 VDE 0113-1, end-to-end connection of the protective grounding
conductor system, or DIN VDE 0701-0702, protective grounding conductor
inspection).
13
14
15
Fig. 18: Electrical connections
Sensor configuration: "Basic":
11
12X1: Feed-in/voltage supply
12
15X1: Enable signal 24 VDC (M12 x 1, 8-pole) ‒ Customer interface
13
14X1: Mini USB service interface
Sensor configuration: "Advanced":
14
16X1: M12 x 1 sensor evaluation (wired at the plant)
Sensor configuration: "Premium"
15
21X1: Multi-Ethernet interface, network input
16
21X2: Multi-Ethernet interface, network input