"Basic" configuration
Voltage
3P 380 V ... 480 VAC (-15 % / +10 %)
Frequency
50/60 Hz
Assignment
L1/L2/L3/PE
Rotating field
Rotating field right
Pre-fuse,
Power 1.5 kW → maximum 10 A
customer side
Power 2.2 kW → maximum 16 A
Power 3.0 kW → maximum 20 A
Power 4.0 kW → maximum 20 A

7.5.2 Mating connector assignment to port 15X1:

Enable signal 24 VDC (M12 x 1, customer side)
Connect the mating connector (optionally available, refer to chapter 17.3
"Accessories") for power supply, see fig. 14, as interface to the superior machine
control system:
Pin 1: 24 VDC supply for the hydraulic power unit
Pin 2: 24 VDC output if the hydraulic power unit is ready for operation (machine-
side bridging with pin 3 without additional enable signal)
Pin 3: 24 VDC input for external enable signal: Hydraulic power unit is put into
operation
Pin 4: 0 VDC (reference ground pin 1)
Pin 5: 24 VDC input for acknowledgment of faults/errors
Pin 6: "Advanced" and "Premium" configuration only
Pin 7
24 VDC inputs for selection of up to four
and
pre-set parameter sets,
Pin 8:
see table 5, for various pressure ratings
-15X1
1 (WH)
2 (BN)
M12x1
1
2
A-coded
-W
-EXT
External
Fig. 14: Assignment of port 15X1: Enable signal 24 VDC
3 (GN)
4 (YE)
5 (GY)
3
4
5
Bridge closed = enable internal
Bridge open = enable external
CytroPac, RE 51055-B/06.17, Bosch Rexroth AG
Assembly
37/84
6 (PK)
7 (BU)
8 (RD)
6
7
8