2.4

Pressure Reducer with Primary Low-Pressure Warning Device

The pressure reducer incorporates a fail-open valve design. The pressure reducer connects to the
cylinder valve assembly with a handwheel assembly. The handwheel assembly is available with two
cylinder connection types (threaded, quick-connect). Both connection types include a sintered filter to
capture particulates. The pressure reducer includes a bell alarm for low pressure that actuates
between 33 and 37 percent of the SCBA's rated service pressure during use.

2.4.1 Rapid Intervention Crew/Company Universal Air Connection (RIC UAC)

The pressure reducer is equipped with a rapid intervention crew/company universal air connection
(RIC UAC) fitting. The RIC UAC fitting is designed to be used by rapid intervention teams for emer-
gency filling operations. The SCBA includes an automatically resetting pressure-relief valve to vent
excess pressure if the SCBA is overpressurized during an emergency filling operation.
2.5

Cylinder and Cylinder Valve Assembly

The cylinder and cylinder valve assembly is available in three rated service pressures (2216 psig,
4500 psig, 5500 psig). The 2216 psig cylinder and cylinder valve assembly is available in one rated
service time (30 minutes) and one material option (carbon). The 4500 and 5500 psig cylinder and
cylinder valve assemblies are available in three rated service times (30, 45, 60 minutes) and one
material option (carbon).
The cylinder valve assembly includes a large pressure gauge with a photo luminescent face. The
handwheel for the cylinder valve assembly is available in two types (standard, locking). The locking
handwheel requires a single action to open and two actions (pull and turn) to close the valve to mini-
mize inadvertent closure. The cylinder valve assembly includes a pressure-relief device to vent pres-
sure safely if the cylinder is overpressurized. The cylinder valve assembly can be equipped with a
male quick-connect adapter to enable connection to a female quick-connect handwheel assembly.