4.11 Remote Quick-Fill System

(1)
Make sure all of the screws in the Remote Quick-Fill system manifold are in position and tightly
installed.
(2)
Make sure the U-clip is in position behind the plate on the back of the manifold.
(3)
Make sure there is no dirt or debris in the openings of the UAC fittings.
(4)
Make sure the dust cap is attached securely.
(5)
Make sure the protective sleeve on the remote Quick-Fill hose does not have tears and cuts. If
the sleeve has tears or cuts, remove the SCBA from service to inspect the Quick-Fill hose and
replace the sleeve.
(6)
Make sure the Quick-Fill hose does not have twists or kinks.

4.12 Quick-Fill Pouch

(3)
Make sure the quick-connect fittings operate correctly and are
secure.
(4)
Make sure dust caps are attached securely to the male and female
quick-connect fittings.
(5)
Make sure the hose is in a smooth coil in the ExtendAire II pouch
and does not have twists or kinks.
(6)
Put the manifold end of the hose in position toward the flap opening
to make sure it is accessible in an emergency breathing situation.
(7)
Make sure the emergency hose does not have nicks, cuts, or abra-
sions.
(1)
Make sure the Quick-Fill pouch does not have cuts, tears, abra-
sions, or damage due to heat or chemical exposure.
(2)
Make sure the Quick-Fill pouch can securely hold and protect the
emergency hose.
(3)
Make sure the Quick-Fill pouch is attached securely to the carrier
and harness.
(4)
Make sure each snap on the Quick-Fill pouch flap is in position and
fastened securely.
G1 SCBA 2018 Edition
Visual Inspections
26