2.6.2 Power Module

The power module distributes the G1 SCBA power and provides all of the information for the control
module, regulator, and speaker module.
The power module is connected to the backplate. The power module connects to the alkaline or
rechargeable battery module, emits audible PASS alarms and pre-alarms, and has four buddy lights.
The power module has the following features:
Rapid Intervention Team (RIT) light that comes on when a low-pressure alarm (configurable to
medium-pressure alarms) occurs to make it easier to see the UAC in the dark.
Data-logging function that records information about the SCBA while the control module is turned
on.
Internal real-time clock that is automatically set to UTC (Coordinated Universal Time) to download
logs and show time based on PC settings.
Radio transmitter for telemetry module, if applicable

2.6.3 Battery Module

The battery module is available in alkaline and rechargeable versions. The alkaline battery module
contains six replaceable, alkaline, C-cell batteries. The rechargeable battery module contains non
replaceable lithium ion cells. When it is necessary to replace or recharge the batteries, the power
module emits an audible tone, the control module display shows an empty battery icon, and a yellow
LED flashes on the HUD.

2.6.4 Firmware

The G1 SCBA firmware can be updated via Bluetooth
software. For detailed instructions about the upgrade process, refer to the Operating Manual: MSA
®
A2
Software, Accountability Control Software (P/N 10162374).
2.7

Carrier and Harness Assembly

The carrier and harness assembly is designed to position the SCBA on the user securely and comfort-
ably. The carrier and harness assembly includes an ergonomic backplate, a cylinder band, and fully
adjustable shoulder and waist straps.
The backplate includes large handles to facilitate handling and storage.
The metal cylinder band and latch securely retain the cylinder and provide a rigid opening to enhance
cylinder installation and removal.
®