9.5

Button Functions

9.5.1 RESET Buttons (Green)

Both RESET buttons have the same function. Push either RESET button to do the following,
depending on the context:
Use a single short push to:
Activate the backlight and refresh the HUD (in intermittent mode)
Toggle between primary and second screens
TIC Mode Only: Toggle between thermal image color palettes
Use a short double push to:
Reset the PASS pre-alarm (or shake the control module to reset it)
Reset the PASS full alarm
Confirm evacuation
Turn the device off (when below 200 psig)
Clear primary alarms
Simultaneously push both buttons to:
Go into RFID mode

9.5.2 ALARM Button

To activate a PASS full alarm, push and hold the ALARM button. A PASS full alarm can be activated
when the SCBA is on or off.
9.6

Integrated TIC

Use a single, long push of either green RESET button on the control module to go into or out of TIC
mode.
While in TIC mode, use single, short pushes of either green RESET button to toggle between palettes.
Five different color palettes can be added to the SCBA via custom configuration. For more information,
refer to the Operating Manual: MSA A2
(3)
Put the ID tag over the RFID reader on the power module.
The RFID reader is on the SCBA backplate on the user's
right side.
When the reading is complete, the control module will
show the ID tag information and emit a beep.
(4)
If the control module does not show the ID tag informa-
tion, do Steps (1) through (3) again.
®
Software, Accountability Control Software (P/N 10162374).
G1 SCBA 2018 Edition
Control Module
56