Turning the Control Module Off

(1)
Upon returning to fresh air and doffing the SCBA, turn the handwheel clockwise to close the
cylinder valve fully.
(2)
Turn the regulator bypass knob counterclockwise to open the regulator bypass valve, or if
equipped, push the purge button, to release all pressure from the SCBA.
(3)
When the pressure decreases below 200 psi, double-push the green RESET button to turn the
control module off.
The shutdown sequence will show on the screen, and the lights on the control and power
modules will stop flashing.
G1 SCBA 2018 Edition
Control Module
57
US