Id Tagging; Name Id Tag; Team Id Tag - MSA G1 SCBA Operating Manual

Niosh cbrn/nfpa 2018 edition
Hide thumbs Also See for G1 SCBA:
Table of Contents

Advertisement

Thermal
Thermal alarm
enabled
Thermal alarm
active
9.4

ID Tagging

WARNING!
When scanning an ID tag, make sure the ID tag touches the power module. If it does not, the PASS
device can lock up. If a lockup occurs, remove the battery module from the SCBA, wait 30 seconds,
and then install the battery module.
Failure to obey this warning can result in serious injury or death.
Before use, make sure the ID tag does not have cracks or other damage. If the ID tag is damaged,
discard it and replace it with a new ID tag.

9.4.1 Name ID Tag

A name ID tag (P/N 10083875) is used to assign a user's name to an SCBA. By default, the name ID
tag must be scanned into the power module at the start of each shift (every 24 hours) or before each
use. The name assigned to the SCBA shows on the MSA A2 accountability system software and the
data log within the SCBA.
For more information about ID tags, or to change the default setting so a name ID tag can be assigned
permanently to the SCBA (until a new name ID tag is scanned), refer to the Operating Manual: MSA
®
A2
Software, Accountability Control Software (P/N 10162374).

9.4.2 Team ID Tag

A team ID tag is used to assign a team/truck and position to an SCBA. If a team ID tag is scanned into
the power module but a name ID tag is not, the team ID will show on the MSA A2 accountability system
software. When a team ID tag is scanned into the power module, the team ID stays with the SCBA
until another team ID tag is scanned. If a team ID or name ID has not been assigned to the SCBA, the
power module serial number shows as the firefighter's ID when the SCBA is logged onto the base
station.
Bluetooth
Long-distance Radio
Connection
established
Connection lost
No Connection
G1 SCBA 2018 Edition
Good connec-
Five green segments
tion
Warning:
Four green segments
Loss of link
Hardware
Three green segments
failure
Capable, no
Two yellow segments
connection
One red segment:
Charge or replace battery,
do NOT use device
Control Module
Battery
53
US