Main Parameters List - gefran ADL300 Installations

Vector inverter for lifts with asynchronous/synchronous motors
Table of Contents

Advertisement

11 Main Parameters List

Menu
Parameter
4.3
554
0
Easy
1
Expert
The Easy mode gives access to a list of parameters that can be used for rapid drive commissioning. This type of configuration is
suitable for the majority of applications.
Setting the parameter to Expert gives access to all the parameters in the firmware. This mode allows an extremely high level of
customization to be achieved in order to exploit the potential of the ADL300 to the full.
Menu
Parameter
4.8
448
This parameter enables for the undervoltage threshold to be configured on the DC link. This parameter prevents the drive from opening
the brake in emergency conditions without a DC link being supplied correctly.
Menu
Parameter
4.17
580
Transfers the standard factory settings to the drive memory ("Def" column in the parameters table).
Menu
Parameter
4.19
6100
Select the Asynchronous motor control mode. The drive is reset and restarts in the new control mode.
To perform this operation via keypad, see chapters 8.2.9 and 8.2.15 of the ADL 300 Quick Start Guide.
Important: the default parameters including the LIFT application are reloaded. This can only be done with the drive disabled.
Menu
Parameter
5.1.1
11002
Selection of the unit of measure for speed references.
0
Hz
(output frequency)
1
m/s
(cabin speed and depends on the mechanical constant)
2
Rpm
(speed of the motor shaft)
3
USCS
(US units: fpm, ft/s2, ft/s3)
When the unit of measure is modified the conversion constants are re-calculated, the units of measure are changed in the parameter list
and the multispeed values are converted into the new unit of measure (the result may contain approximations due to the conversion
calculations).
A variable representing the speed of the cabin in m/s (fpm) is always available (PAR 12210).
There are fixed units of measure for the acceleration and deceleration parameters m/s² (ft/s2), and for jerks m/s³ (ft/s3).
Menu
Parameter
5.1.2
11020
Setting of the multispeed 0 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
This setting is taken as the default low speed value.
Menu
Parameter
5.1.3
11022
Setting of the multispeed 1 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
This setting is taken as the default high speed value.
Menu
Parameter
5.1.4
11024
Setting of the multispeed 2 value. Can be selected via digital input, fieldbus, etc.
The selected value is the reference for the S-shaped lift ramp.
This setting is taken as the default maintenance speed value.
Menu
Parameter
ADL300 - Fast installations and commissioning
Description
Access mode
Description
Emergency UV (V)
Description
Load default
Description
Load asynch control
Description
Travel units sel (Hz)
Description
Multi speed 0 (m/s)
Description
Multi speed 1 (m/s)
Description
Multi speed 2 (m/s)
Description
Default Value
Min
Easy
0
Default Value
Min
CALCF
0.0
Default Value
Min
0
0
Default Value
Min
0
0
Default Value
Min
0
0
Default Value
Min
0.10
-10000
Default Value
Min
1.00
-10000
Default Value
Min
0.40
-10000
Default Value
Min
Max
1
Max
CALCF
Max
1
Max
1
Max
2
Max
10000
Max
10000
Max
10000
Max
Pag. 47 of 52