gefran ADL300 Installations page 50

Vector inverter for lifts with asynchronous/synchronous motors
Table of Contents

Advertisement

Menu
Parameter
5.7.6
11230
Setting of the source for the third multispeed selection bit.
See the list on PAR 11226
Menu
Parameter
14.1
2000
Set the motor rated voltage as indicated on the data plate. This is the voltage the drive must supply
at the motor rated frequency.
Menu
Parameter
14.2
2002
The motor rated current at its rated power (kW / Hp) and voltage (indicated on the motor data plate).
If using a single drive to control several motors connected in parallel (only possible in the SSC mode), enter a value that corresponds to
the sum of the rated currents of all the motors; in this case do not perform any "self-tuning operations".
Menu
Parameter
14.3
2004
Rated speed of the motor with full load in rpm. In some motors the synchronous speed (e.g. 1500 rpm for a 4-pole motor) and slippage,
i.e. the loss of revolutions between the motor idling condition and the rated load condition (e.g. 80 rpm), is indicated. Enter the following:
synchronous speed - slippage.
Menu
Parameter
14.4
2008
Setting of the number of motor pole pairs.
Menu
Parameter
14.5
2010
Setting of the ratio between the torque generated and the rated current of the motor.
Menu
Parameter
14.6
2012
Setting of the electromotive force constant, which represents the ratio between the motor voltage and its rated speed (this can be
calculated by dividing the torque constant by √3).
Menu
Parameter
14.7
2020
Saves the set motor data in the drive. This command must be supplied last after entering the appropriate values of all the parameters
listed above. This means calculating the normalization factors (a) and estimated values for the motor parameters (b). The drive cannot
be started until the Take parameters command has been set.
Menu
Parameter
14.8
2024
Performs self-tuning with the motor coupled to the transmission. The self-tuning procedure may cause limited rotation of the motor shaft.
To perform self-tuning, follow the procedure described for the previous parameter.
Menu
Parameter
14.9
2028
Indication of the status of parameter saving.
0
Required
1
Done
The parameter displays the Required message when the motor parameters that have been entered need to be saved. When they have
been saved the parameter indicates Done.
Menu
Parameter
14.10
2030
Indication of the status of execution of motor parameter self-tuning.
0
Required
1
Done
ADL300 - Fast installations and commissioning
Description
Multi speed S2sel
Description
Rated voltage (V)
Description
Rated current (A)
Description
Rated speed (rpm)
Description
Pole pairs
Description
Torque constant (Nm/A)
Description
EMF constant (Wb)
Description
Take parameters
Description
Autotune still
Description
Take status
Description
Autotune status
Default Value
Min
1220
0
Default Value
Min
SIZE
50.0
Default Value
Min
SIZE
1.0
Default Value
Min
SIZE
10.0
Default Value
Min
SIZE
1
Default Value
Min
SIZE
0.1
Default Value
Min
SIZE
0.0
Default Value
Min
0
0
Default Value
Min
0
0
Default Value
Min
Required
0
Default Value
Min
Required
0
Max
35
Max
690.0
Max
1500.0
Max
32000.0
Max
60
Max
120
Max
100.0
Max
1
Max
1
Max
0
Max
0
Pag. 50 of 52