6.3 Motor & Encoder Setup
6.3.1

Motor data setup

Menu
14.1
Rated Voltage (possible range) 200 – 460 Volts.
Menu
14.2
Rated current (possible range) 1 – 1500 Ampere.
Menu
14.7
Power Factor (Async motor only).
Menu
14.3
Rated Speed (possible range) 10 – 32000 rpm.
Menu
14.4
Number of Pole Pairs in the range 1 – 60.
Synchronous menu
14.5
Torque generated at in the range 0.1 – 120.
Asynchronous menu
14.5
Rated motor power
6.3.2

Encoder data setup

Menu
15.10
Encoder Type Selection
0 None (Open Loop Elevators)
1 Digital FP
ADL300 - Fast installations and commissioning
Figure 8.1: Motor data setup
Parameter
2000
Parameter
2002
Parameter
Description
2012
Rated Power Factor
Parameter
2004
Parameter
2008
Parameter
2010
Parameter
2010
Parameter
2132
Description
Rated Voltage
Description
Rated Current
Description
Rated Speed
Description
Pole Pairs
Description
Torque Constant
Description
Rated Power
Description
Encoder Mode
Default Value
-
Default Value
-
Default Value
0,83
Default Value
-
Default Value
-
Default Value
-
Default Value
-
Default Value
Sinus SINCOS
Set to
200 - 460
Set to
1.0 - 1500
Set to
0,60 – 0,95
Set to
10 - 32000
Set to
1 - 60
Set to
1 - 60
Set to
1 - 1500
Set to
See below
Pag. 29 of 52