Age/Hold

5.9 Warning

5.9.1

Fault Alarm

When any selected fault event happens, the Fault LED on the switch panel will light up and the
electric relay will signal at the same time.
5.9.2

System Warning

SYSLOG Setting
The SYSLOG is a protocol that transmits event notifications across networks.
ORing Industrial Networking Corp
If at least one user module has decided to block this MAC
address, it will stay in the blocked state until the hold time
(measured in seconds) expires. If all user modules have decided
to allow this MAC address to forward, and aging is enabled, the
Port Security module will periodically check that this MAC
address still forwards traffic.
If the age period (measured in seconds) expires and no frames
have been seen, the MAC address will be removed from the MAC
table. Otherwise a new age period will begin.
If aging is disabled or a user module has decided to hold the MAC
address indefinitely, a dash (-) will be shown.