Required Tools and Equipment (ETSI)
NTP-G303 Configure a Cisco Catalyst 2950 for a ONS 15454
Multishelf Node
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
When Cisco Catalysts are used in a multishelf node configuration, the Cisco Catalysts can be used for
Note
other applications as long as they do not interfere with the VLAN settings of the multishelf node
configuration.
At the Cisco IOS command line interface (CLI) for the Catalyst switch, enter the following spanning tree
Step 1
commands:
Switch(config)#spanning-tree mode rapid-pvst
Switch(config)#no spanning-tree optimize bpdu transmission
Switch(config)#spanning-tree extend system-id
Step 2
Enter the following commands to configure Port 1:
(Switch(config)#interface FastEthernet0/1
(Switch(config-if)#switchport trunk allowed vlan public VLAN ID,private VLAN ID
(Switch(config-if)#switchport mode trunk
(Switch(config-if)#switchport nonegotiate
Step 3
Enter the following commands to configure Ports 2 through 12. Replace port with the port number (2
through 12) and repeat for each port.
(Switch(config)#interface FastEthernet0/port
(Switch(config-if)#switchport access vlan private VLAN ID
(Switch(config-if)#switchport mode access
Step 4
Enter the following commands to disable Ports 13 through 21 and disable VLAN management:
(Switch(config)#interface FastEthernet0/13 - 21
(Switch(config-if)#shutdown
Step 5
Enter the following commands to configure Port 22:
(Switch(config)#interface FastEthernet0/22
(Switch(config-if)#switchport trunk allowed vlan public VLAN ID,private VLAN ID
(Switch(config-if)#switchport mode trunk
(Switch(config-if)#spanning-tree port-priority 0
Enter the following commands to configure Ports 23 and 24. Replace port with the port number (23
Step 6
through 24) and repeat for each port.
(Switch(config)#interface FastEthernet0/port
(Switch(config-if)#switchport mode access
Cisco ONS 15454 DWDM Procedure Guide, Release 9.2
1-84
This procedure uses Cisco IOS to configure the Cisco Catalyst 2950 for a
multishelf node configuration. For more information about the
Catalyst 2950, refer to the Catalyst 2950 product documentation.
None
NTP-G302 Connect the ONS 15454 Multishelf Node and Subtending
Shelves to a Catalyst 2950, page 1-83
Required
Onsite or remote
Superuser
Chapter 1
Install the Cisco ONS 15454 Shelf Assembly
78-19286-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15454Ons 15454 m2Ons 15454 m6

Table of Contents