Cisco ONS 15454 Series Procedure Manual page 167

Dwdm
Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 1
Install the Cisco ONS 15454 Shelf Assembly
Note
Return to your originating procedure (NTP).
Step 9
DLP-G34 Install the AIC-I Card
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
When installing cards, allow each card to boot completely before installing the next card.
Step 1
Open the latches/ejectors on the card.
Step 2
Use the latches/ejectors to firmly slide the card along the guide rails in Slot 9 until the card plugs into
the receptacle at the back of the slot.
Step 3
Verify that the card is inserted correctly and close the latches/ejectors on the card.
Note
Verify the following:
Step 4
78-19286-01
Alarm LEDs might be on; disregard alarm LEDs until you are logged into CTC and can view the
Alarms tab.
This task installs the AIC-I card. The AIC-I card provides connections for
external alarms and controls (environmental alarms).
AIC-I card
DLP-G33 Install the TCC2, TCC2P, or TCC3 Card, page 1-75
As needed
Onsite
None
It is possible to close the latches/ejectors when the card is not completely plugged into the
backplane. Ensure that you cannot insert the card any further.
The red FAIL LED blinks for up to 10 seconds.
If the red FAIL LED does not turn on, check the power.
Note
The PWR A and PWR B LEDs become red, the two INPUT/OUTPUT LEDs become amber, and the
ACT LED turns green for approximately 5 seconds.
The PWR A and PWR B LEDs turn green, the INPUT/OUTPUT LEDs turn off, and the green ACT
LED remains on.
Note
It might take up to 3 minutes for the PWR A and PWR B LEDs to update.
Note
If you insert a card into a slot provisioned for a different card, no LEDs turn on.
Required Tools and Equipment (ETSI)
Cisco ONS 15454 DWDM Procedure Guide, Release 9.2
1-79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15454Ons 15454 m2Ons 15454 m6

Table of Contents