Back Gauge Motor (X Axis). This motor is used to change the position of the back-
gauge support arm. This changes how far in the material is positioned before the
V
bend. The back gauge and the material stops may be manually adjusted as needed
by the operator for the specific bend desired. This includes being lowered to not be
used at all.
Door Closed Limit Switch. This limit switch is used to interlock the door with the
system. When the door is open, the main motor will not run. ALWAYS keep the door
W
closed during operation. Use proper Lock out Tag out procedures when opening the
door for service or adjustments.
Main Power Disconnect Switch. Controls the main power supply On/Off function. Turn
power off when the machine is not being used or attended. Has the ability to be
X
locked out (customer supplies the lock) to prevent unauthorized use. Use proper Lock
out Tag out procedures for service or adjustments.

Switch and Button Functions

WARNING:
the main disconnect switch "OFF". Also turn off and Lock Out the electrical supply
source to this machine. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT
IN FATAL OR SERIOUS INJURY.
MAIN DISCONNECT SWITCH – The safety disconnect switch turns
power on to the machine when in the "ON" position. The power
indicator lamp (A) will be illuminated.
POWER INDICATOR LIGHT – The white indicator lamp (A) will be
illuminated when the machine is properly powered ON.
POWER KEY SWITCH – The key switch (B) controls the power to
the operating system of the machine. When turned to the ON
position the controller will be powered On. The main disconnect must
be turned ON.
PUMP START PUSHBUTTON – When the system is properly set, (doors and guards closed
and latched) depressing the pump start button (C) will start and run the main motor. The green
light on the pump start button will be lit. The main motor must be running before the controller
will allow for programming and setting of the X and Y axis's.
RESET PUSHBUTTON – When operation is interrupted due to a safety limit switch activation,
the system will be locked out until the limit switch is satisfied (door or guard closed) and the
Reset button (D) is pressed. This clears the system to return to normal operation.