Press Functions; Main Disconnect Switch; On And Off Switches; Emergency Switch - Baileigh Industrial HSP-30M Operator's Manual

30 ton hydraulic shop press
Table of Contents

Advertisement

PRESS FUNCTIONS

Main Disconnect Switch

The main disconnect switch is located on the
front of the electrical cabinet.
 Turn the switch to the ON position to supply
power to the electrical controls. The red
indicator will light up as long as the
disconnect is ON.
 Turn the switch to the OFF positon to
remove power to the operation controls.

On and Off Switches

The on and off switches are positioned on the
front of the electrical cabinet.
 Press and release the green button will start
the motor of the hydraulic unit. There will be
no movement of any parts after the motor
runs. The green indicator will light up as long
as the motor is running.
 Pushing the red button will stop the motor of
the hydraulic unit. All parts will stay in the
position they are at that moment.

Emergency Switch

The emergency switch is located on the front of
the electrical cabinet.
In the event of incorrect operation or dangerous
conditions, the machine can be stopped
immediately by pressing the E-STOP button. All other parts will stay in the position they are at
the moment. Twist the emergency stop button clockwise (cw) to reset. Note: Resetting the E-
Stop will not start the machine.
To restart the hydraulic unit again
 Make sure the incorrect or dangerous situation is solved.
 Reset the red button by turning it counter clockwise. The button cap will pop-up again.
 Actuate the hydraulic lever to the up and down position to relieve pressure from the hydraulic
system.
 Push the green start button to start the hydraulic pump motor.