Safety Equipment - Baileigh Industrial BP-3305CNC Operator's Manual

Hydraulic press brake
Table of Contents

Advertisement

High/low speed selection, Press the corresponding double plus or double
minus key along with the slow speed key to double the travel speed for the axis that is
highlighted on the Single screen.

Safety Equipment

WARNING:
machine so that the operator is aware of how it functions. Never remove, change,
alter, disable, disconnect, etc. any of the safety equipment.
Light Curtain
Your press brake is equipped with an opto-electronic light curtain system mounted inside the
side guard for point of operation safeguarding. This system is designed to safeguard the entire
operating area from press bed to full opening, while maintaining user safety distance.
Being designed to cover the entire working area, some applications may interrupt the light
curtain causing the machine cycle to stop. These applications may include, but are not limited
to, certain box shapes, small parts, etc... Accessories and tool sets may also interfere with light
curtain operation. Accessories installed (including the optional supplied support arms) and
mounted above bed level, extending toward the operator (past the light curtain) will stop the
machine cycle. If your application interferes with light curtain operation, the end-user will need to
re-mount or replace the safeguard system for their application per ANSI standard B11.3 Chapter
8, section 5.
Safety Guards
There are safety guards at side and back of machine. This is to prevent personal or objects from
entering these areas while the machine is in operation. These safety guards are connected
electrical to the system by safety switch. If any of the safety switches is activated, the machine
will not operate.
Note: When the light of curtain is interrupted, or the safety guard switch is
activated, you will need to push the reset button to enable the electrical system.
Emergency Stop
There are 2 emergency stop buttons on the machine located on the hanging control station and
the foot pedal control station. In the event of incorrect operation or dangerous conditions, the
machine can be stopped immediately by pressing the E-STOP button. Twist the emergency stop
button clockwise (cw) to reset. Note: Resetting the E-Stop will not start the machine.
This section describes the safety equipment installed on this