Connecting The Rack Mount Tpu And The Sonarpro Workstation - Klein 4900 Series Operation And Maintenance Manual

Table of Contents

Advertisement

Connecting the Topside System Components
Connect the tow cable to the TOWFISH connector on the SP-III TPU.
4.
Connect the AC power cable to the 120/240 VAC connector on the SP-III
5.
TPU and to the AC power source, or connect the DC power cable to the 12
VDC connector on the SP-III TPU and to a 12 VDC power source, or both.
To run the laptop computer from AC power, connect it to its power supply and
6.
connect the power supply to the AC power source.
The following connections are optional:
7.
Connect the 1PPS IN connector on the SP-III TPU to the 1PPS output of the
shipboard GPS. A user supplied BNC-to-BNC cable is required.
Connect the T/F TRIG connector on the SP-III TPU to the trigger input of an
8.
external sonar system. A user supplied BNC-to-BNC cable is required.
Connect the RESP TRIG connector on the SP-III TPU to the trigger input of a
9.
USBL system. A user supplied BNC-to-BNC cable is required.
3.6.2
Connecting the Rack Mount TPU and the SonarPro
Workstation
The following supplied cables are used to connect the Rack Mount TPU and the
SonarPro Workstation:
• Ethernet crossover cable
• AC power cords (2)
• Deck cable
WARNING Before connecting the topside system components, verify that
the Rack Mount TPU is turned off and that its power cord is disconnected.
Failure to follow this practice may result in personal injury or damage to
the towfish or to the Rack Mount TPU electronics, or to both. For the location of the
power switch, refer to "Topside System Controls and Indicators" on page 3-15.
To connect the Rack Mount TPU and the SonarPro Workstation:
1.
Connect the Ethernet crossover cable to the ETHERNET connector on the
Rack Mount TPU and to either one of the two the ETHERNET connectors on
the SonarPro Workstation.
Connect the monitor to the DVI connector on the SonarPro Workstation and
2.
connect the monitor power supply to the AC power source.
Connect the keyboard and the mouse to any two of the six USB connectors on
3.
the SonarPro Workstation.
3-13