Chapter 2 Specifications; Sp-Iii Tpu; Rack Mount Tpu - Klein 4900 Series Operation And Maintenance Manual

Table of Contents

Advertisement

2-2

CHAPTER 2 Specifications

Range:
Near nadir coverage:
2.2

SP-III TPU

Size:
Weight:
Ingress protection:
Outputs:
Output data format:
Operating system:
Navigation input:
Input voltage:
Power consumption:
Operating temperature:
2.3

Rack Mount TPU

Size:
Weight:
Chassis type:
Input voltage:
Series 4900 Sonar System Operations and Maintenance Manual
10, 15, 20, 25, 30, 40, 50, 60, 75, 100,
120, 150, and 200 meters at 455 kHz
10, 15,20, 25,30, 40, 50, 60, and
75 meters at 900 kHz
25% of altitude per side
50.24 cm (19.78 in.) wide
17.1 cm (6.72 in.) high
32.7 cm (12.89 in.) deep
6.8 kg (15.0 lb)
Designed to IP-65
100BaseTx, Ethernet LAN, RS-232
serial ports (2)
Selectable Sonar Data Format (SDF),
Extended Triton Format (XTF), or both
Linux
NMEA 0183
88–264 VAC, 47–63 Hz or 12 VDC
75 w (nominal)
0–40°C
8.9 cm (3.5 in.) H
48.3 cm (19.0 in.) W
35.6 cm (14.0 in.) D
7.6 kg (17 lb)
2U, 19-inch rack mount
88–264 VAC, 47–63 Hz
P/N 11210091, Rev. 02