How to connect wiring to the terminal
For stranded wiring
(1) Cut the wire end with cutting pliers, then strip the
insulation to expose the stranded wiring about 10 mm
and tightly twist the wire ends.
Stranded wire
(2) Using a Phillips head screwdriver,
screw(s) on the terminal board.
(3)
Using a ring connector fastener or
each stripped wire end with a ring pressure terminal.
(4) Place the ring
pressure terminal, and replace and tighten
the removed terminal screw using a
Special
Screw
washer
Ring pressure
terminal
Terminal board
Wire
Ring
pressure
terminal
remove the terminal
pliers, securely clamp
screwdriver.
Screw and
Special washer
Ring
pressure
terminal
Wire
Examples of shield
(1) Remove cable coat not
(2) Unbraid the braided shield
unbraided shield
shield wires by
wrapping insulating
(3) Remove coat of
(4) Attach ring pressure terminals to the
the shield wires insulated in Step
1-10-1-1-5
wires
to scratch braided
shield.
carefully and
twist the
wires
tightly together.
Insulate the
covering them with
an
insulation tube or
tape
around them.
Insulating tape
Shield mesh
signal wire.
Insulating
tape
Shield
mesh
signal wires and
(2).