IMPORTANT!
Please Read Before Starting
This air conditioner must be installed by the sales dealer
or installer.
This information is provided for use only by authorized
persons.
For safe installation and trouble-free operation, you
must:
This Installation Instructions is for the indoor unit and
read the Installation Instructions of the outdoor unit as
well.
Carefully read this instruction booklet before beginning.
This air conditioner is required to have the remote
controller which is adaptable to nanoe™X function.
Follow each installation or repair step exactly as shown.
This air conditioner shall be installed in accordance with
National Wiring Regulations.
That compliance with national gas regulations shall be
observed.
The product meets the technical requirements of
EN/IEC 61000-3-3.
Pay close attention to all warning and caution notices
given in this manual.
This symbol refers to a hazard or
WARNING
unsafe practice which can result in
severe personal injury or death.
This symbol refers to a hazard or
unsafe practice which can result
CAUTION
in personal injury or product or
property damage.
If Necessary, Get Help
These instructions are all you need for most installation
sites and maintenance conditions. If you require help for
a special problem, contact our sales/service outlet or your
certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this document.
WARNING
Do not use means to accelerate
the defrosting process or to clean,
other than those recommended by
the manufacturer.
The appliance shall be stored
in a room without continuously
operating ignition sources (for
example: open flames, an operating
gas appliance or an operating
electric heater).
Auxiliary devices which may be a
potential ignition source shall not
be installed in the duct work.
Examples of such potential ignition
sources are hot surfaces with a
temperature exceeding 700°C and
electric switching devices.
For appliances connected via an
air duct system to one or more
rooms, only auxiliary devices
approved by the appliance
manufacturer or declared suitable
with the refrigerant shall be installed
in connecting ductwork.
Do not pierce or burn.
Be aware that refrigerants may not
contain an odour.
The following checks shall be
applied to installations using
flammable refrigerants.
Appliance shall be installed,
operated and stored in a room with
a floor area larger than [Amin] m
As for [Amin], see the section
"CHECK OF DENSITY LIMIT".
SPECIAL PRECAUTIONS
WARNING
ELECTRICAL SHOCK CAN
CAUSE SEVERE PERSONAL
INJURY OR DEATH. ONLY A
QUALIFIED, EXPERIENCED
ELECTRICIAN SHOULD
ATTEMPT TO WIRE THIS
SYSTEM.
• Do not supply power to the unit until
all wiring and tubing are completed or
reconnected and checked.
• Highly dangerous electrical voltages are
used in this system. Carefully see the
wiring diagram and section 2 when wiring.
Improper connections and inadequate
grounding can cause accidental injury
or death.
• Connect all wiring tightly. Loose wiring
may cause overheating at connection
points and a possible fire hazard.
Provide a power outlet to be used
exclusively for each unit.
Provide a power outlet exclusively for
each unit, and full disconnection means
having a contact separation by 3 mm
in all poles must be incorporated in the
fixed wiring in accordance with the wiring
rules.
To prevent possible hazards from
insulation failure, the unit must be
grounded.
1
When Wiring
.
2