1
1-12. Capacity Table
2. Heating Capacity Performance Data
Type U3 Series
Power
Model
Source
S-3650PU3E
220V-230V-240V
(S-3650PU3E(36))
50Hz 1phase
U-36PZ3E5
S-3650PU3E
220V-230V-240V
(S-3650PU3E(50))
50Hz 1phase
U-50PZ3E5
S-6071PU3E
220V-230V-240V
(S-6071PU3E(60))
50Hz 1phase
U-60PZ3E5
S-6071PU3E
220V-230V-240V
(S-6071PU3E(71))
50Hz 1phase
U-71PZ3E5
Ambient
Return
-16°C
Air
DB
TC
IPT
16
2.6
0.817
20
2.5
0.869
24
2.5
0.924
16
3.7
1.35
20
3.6
1.44
24
3.6
1.52
16
4.6
1.46
20
4.6
1.54
24
4.5
1.65
16
4.7
1.66
20
4.7
1.78
24
4.5
1.90
Outdoor air intake temp(°C W.B.)
-8°C
6°C
TC
IPT
TC
IPT
3.3
0.877
4.7
3.2
0.933
4.6
3.2
0.992
4.5
4.7
1.50
6.5
4.6
1.60
6.4
4.5
1.70
6.3
5.5
1.69
7.1
5.4
1.78
7.0
5.3
1.91
6.9
5.8
1.88
8.2
5.8
2.02
8.1
5.6
2.16
7.8
1-12-2-1-1
TC
:Heating Capacity
IPT :Heating Power Consumption
10°C
TC
IPT
TC
1.00
5.1
1.04
1.06
5.0
1.10
1.13
4.9
1.17
1.73
7.0
1.83
1.84
6.9
1.94
1.95
6.8
2.06
2.09
7.7
2.23
2.20
7.6
2.35
2.35
7.4
2.35
2.30
8.8
2.40
2.40
8.7
2.50
2.50
8.2
2.50
unit : kW
15°C
IPT
5.6
1.10
5.6
1.17
5.5
1.24
7.7
1.92
7.6
2.05
7.4
2.15
8.1
2.11
8.0
2.11
7.9
2.11
8.9
2.25
8.8
2.25
8.6
2.25