2. If you are installing the projector with the optional pedestal (P/N: 163-126100-XX), follow the
instructions provided with that accessory. For more information on available accessories, see
the CineLife+ RGB PLF Specifications Guide (P/N: 020-103074-XX).
3. Position the projector so it is centered and parallel with the theater screen. If space is limited,
aim the projector slightly off-center and use lens offset to center the image on the screen.
Related information
Light intensity hazard distance (on page 7)

Connecting to power

The recommended setup is to provide two hard-wired connections to AC power. When connecting the
projector to AC power, follow all electrical codes for your location.
Warning! If not avoided, the following could result in death or serious injury.
Always connect the ground or earth first to reduce shock hazard.
FIRE HAZARD! Do not use a power cord, harness, or cable that appears damaged.
FIRE AND SHOCK HAZARD! Do not attempt operation unless the power cord, power socket, and
power plug meet the appropriate local rating standards.
SHOCK HAZARD! Do not attempt operation if the AC supply is not within the specified voltage
and current, as specified on the license label.
SHOCK HAZARD! A dedicated, protected ground or earth wire must be installed on the product
by Christie qualified technicians or electricians before it can be connected to power.
A certified electrician must be present during installation to ensure the installation meets the
local electrical code.
Caution! If not avoided, the following could result in minor or moderate injury.
Use an appropriately sized strain relief connector with the knockout plate provided, to ensure
adequate environmental sealing and to prevent the AC supply cable from accidentally being torn
out or rubbing against the knockout plate.
Two, 30A maximum rated, certified wall circuit breakers are required. They must be part of the
building and easily accessible.
Use a minimum of 12 AWG copper wire, grounding included, for the connection of the main AC
supply to the projector's ground lug.
Either copper or aluminum is acceptable as conductor wiring material to the terminal block.
CineLife+ RGB PLF Installation and Setup Guide–CP4450-RGB
020-103072-02 Rev. 1 (09-2019)