3. To open the AC input area of the projector, remove the six screws holding the cover and swing
the cover downwards to open it.
4. Taking the approved line cord for your location, strip the cable jacket on the line cord to
expose a 120 mm length of the bundled wires.
5. Cut the Line (black or brown) and Neutral (white or blue) wires to shorten them to a length
between 80 to 100 mm.
6. Using a wire stripper, strip the insulation from each individual wire to expose 10 mm of bare
wire on the end.
7. Repeat steps 4 to 6 for the second line cord.
8. Pass the wires through the strain reliefs on each knockout plate and through the AC input
cover.
9. For each terminal block, fasten the bare end of the wires into the Ground (G), Line (L), and
Neutral (N) terminal connectors, starting first with the Ground (green) connection, followed by
the Line (black or brown) and Neutral (white or blue) connections.
CineLife+ RGB PLF Installation and Setup Guide–CP4450-RGB
020-103072-02 Rev. 1 (09-2019)
Copyright
2019 Christie Digital Systems USA, Inc. All rights reserved.
©