Default
0
PT (PWM Output Timeout)
Specifies how long both PWM outputs (P0, P1) output a given PWM signal before it reverts to the
configured value (M0/M1). If set to 0, there is no timeout. This timeout only affects these pins when
they are configured as PWM output.
Parameter range
0 - 0xFF (x 100 ms)
Default
0xFF

Location commands

The following commands are user-defined parameters used to store the physical location of the
deployed device.

LX (Location X)

User-defined GPS latitude coordinates of the node that is displayed on Digi Remote Manager and
Network Assistant.
Parameter range
0 - 15 ASCII characters
Default
One ASCII space character (0x20)

LY (Location Y)

User-defined GPS longitude coordinates of the node that is displayed on Digi Remote Manager and
Network Assistant.
Parameter range
0 - 15 ASCII characters
Default
One ASCII space character (0x20)

LZ (Location Z)

User-defined GPS elevation of the node that is displayed on Digi Remote Manager and Network
Assistant.
Parameter range
0 - 15 ASCII characters