AT commands

PD (Pull Up/Down Direction)

The resistor pull direction bit field (1 = pull-up, 0 = pull-down) for corresponding I/O lines that are set
by the PR command.
If the bit is set, the device uses an internal pull-up resistor. If it is clear, the device uses an internal
pull-down resistor. See the PR command for the bit order.
Parameter range
0x0 - 0x7FFF
Default
0x1FBF
RP (RSSI PWM Timer)
The PWM timer expiration in 0.1 seconds. RP sets the duration of pulse width modulation (PWM) signal
output on the RSSI pin. The signal duty cycle updates with each received packet and shuts off when
the timer expires.
When RP = 0xFF, the output is always on.
Parameter range
0 - 0xFF (x 100 ms)
Default
0x28 (four seconds)

DC (Device Controls)

Bit settings to enable or disable certain behaviors.
Bit Description
0
Joiner Global Link Key. Indicates whether a joiner node uses a global link key or a unique
link key.
1
Network Leave Request Not Allowed. Indicates if a router node discards or accepts
network leave commands.
2
Reserved
3
Reserved
Verbose Joining Mode. See
4
Parameter range
0-0xFFFF
Default
0x00
XBee/XBee-PRO® S2C ZigBee® RF Module
Extended Modem Status frame - 0x98
I/O settings commands
for a full description.