3510/3510KP/3512/3512KP System Manual
3510KP/3512KP, 3510KPT/3512KPT
Power Supply
The power supply provides 80 watts of output throughout the system's temperature
range. The expansion power is limited as shown in the following table.
Hazardous Locations Installations
Xycom Automation designed the systems to meet the requirements of Class I,
Division 2 Hazardous Locations applications. Division 2 locations are those
3-28
7.900 [200.66]
1.650 [41.91]
.350 [8.89]
10.850 [275.59]
Figure 3-19. 3510KP/3512KP System Cutout Dimensions (inches [mm])
Available Expansion Current
Voltage
AHIP4+ (5x86
processors)
+5 VDC
+12 VDC
-12 VDC
a
Total expansion power not to exceed 46 watts
b
Total expansion power not to exceed 48 watts
15.800 [401.32]
14.150 [359.41]
15.100 [383.54]
ø.250 [ø6.35]
Available Current
AHIP6+ (Celeron and
a
Pentium II processors)
6.17A
+3.3
1.88A
+5
0.71A
+12
-12
b
9A
6A
1.5A
.45A
Need help?