Power Supply; Hazardous Locations Installations - Xycom 3510T System Manual

Flat-panel industrial pcs
Hide thumbs Also See for 3510T:
Table of Contents

Advertisement

3510/3510KP/3512/3512KP System Manual
3510KP/3512KP, 3510KPT/3512KPT

Power Supply

The power supply provides 80 watts of output throughout the system's temperature
range. The expansion power is limited as shown in the following table.

Hazardous Locations Installations

Xycom Automation designed the systems to meet the requirements of Class I,
Division 2 Hazardous Locations applications. Division 2 locations are those
3-28
7.900 [200.66]
1.650 [41.91]
.350 [8.89]
10.850 [275.59]
Figure 3-19. 3510KP/3512KP System Cutout Dimensions (inches [mm])
Available Expansion Current
Voltage
AHIP4+ (5x86
processors)
+5 VDC
+12 VDC
-12 VDC
a
Total expansion power not to exceed 46 watts
b
Total expansion power not to exceed 48 watts
15.800 [401.32]
14.150 [359.41]
15.100 [383.54]
ø.250 [ø6.35]
Available Current
AHIP6+ (Celeron and
a
Pentium II processors)
6.17A
+3.3
1.88A
+5
0.71A
+12
-12
b
9A
6A
1.5A
.45A