Update Channel Adapter; Procedure With Moss Alone - IBM 3745 Service Functions

Communication controller
Table of Contents

Advertisement

Display/Update CA
Update Channel Adapter
Always check the MOSS state in the MSA (refer to page 1-10), because the procedure is different,
depending on the MOSS state.
Procedure with MOSS Alone
1. You must be in the CDF Display/update func-
tion (see page 9-15).
2. Display the CA (see "Display/Update Channel
Adapters" on page 9-19), then press FS.
3. This screen (
m)
is displayed.
4. Enter the required parameters in
0,
and in
fJ
if applicable (TPS feature installed); see
"CA Display Field Explanations" on page 9-25.
5. Press SEND.
6. The message:
UPDATE OF THE CDF FILE SUCCESSFUL
is displayed.
7. Press Fa to update the other parameters
(screen
Em).
• INTERFACE B information is displayed only if
TPS is installed.
• The ESC address range parameter is not
present if the CA is of type 7 (BCCA).
1. Update the desired fields, under INTERFACE
A, and INTERFACE B. (Refer to "CA Parame-
ters Explanation" on page 9-26 for details.)
2. Press SEND.
3. The following message is displayed:
UPDATE OF THE CDF FILE SUCCESSFUL
9-22
3745 Service Functions
m
CUSTOMER 10:
3745
SERIAL NUMBER:
CCU-A
PROCESS
mfii·'.@J
RUN
STOP-IOC-CHK srOP-CCU-CHK AC
~1AXI~1U~1
ADAPTERS CONFIGURATION: CHANNEL ADAPTERS
5, 6, 7, B
LINE
ADAPTERS
I, 3,
4, 9,
16, II, 12
- - - -- - - - -- -- -- - -- - - -- - - - - - - - - - -- - - - - -- -- - -- - - - - - - -- - - - - - - --- - - -mnl/ dd/yy hh:mn
CDF - DISPLAY/UPDATE: CA
xx
SIiITCH : --
IOC
:
1
CAB
:--
GROUP :
x
SELECT I/O ERROR ALERT
PS 10 : --
CCU
:
A
(Y OR N)
AGDR :
xxxx
TYPE :
xxxx
SELECT TWO PROCESSOR SWITCH MODE
(TPS OR TCS)==>
D
- PRESS SEND
F!
:END
F3:ALARM
F6:QUlT
F7:PREVIOUS CA
IB!J
Figure
9-37. Update a CA
CDF - UPDATE : CA
xx
INTERFACE A
INTERFACE B
CHANNEL BURST LENGTH (4 TO 254)
==>
xxx
CHANNEl PRIORITY (L=LOII,H=HIGH)
==>
x
NSC ADDRESS
(as
TO FF)
==>
xx
DATA STREAMING (Y=YES,N=NO)
==>
x
HIGH SPEED DATA TRANSFER (Y=YES,N=NO)
==>
X
BYTE MULTIPLEXER CHANNEl (Y=YES,N=NO)
==>
x
DATA STREAMING SPEED (1 TO 3)
==>
x
(1=IMB,
2=2~1B,
3=3MB)
ESC ADDRESS RANGE (00 TO FF)
==>
xx - xx
Fl :END
F3:ALARM
-
F6:QUlT
F7:BIIO
Figure
9-38. Update a CA (Second Part)
(