IBM 3745 Service Functions page 105

Communication controller
Table of Contents

Advertisement

TSS Messages
SCROLL IGNORED
Cause: You either requested a scroll forward and the displayed data is at the end of the storage, or you requested a scroll
backward and the displayed data is at the top of the storage.
Action:
None.
SELECT A SCANNER
Cause: You selected a TSS function without having selected a scanner.
Action:
Select a scanner.
SELECTED SCANNER IS NOT A HPTSS: REQUEST IGNORED.
Cause: You selected a TSS function reserved to HPTSS and the selected scanner
IS
a TSS.
Action:
Release the scanner and select an H PTSS.
SPECIFY A DELAYED ALTER
Cause: You requested an address compare function with action start delayed alter, but did not specify the delayed alter opera-
tion.
Action:
Specify the delayed alter operation and resume address compare.
SPECIFY A DELAYED DISPLAY
Cause: You requested an address compare function with action start delayed display, but did not speCify the delayed dIsplay
operation.
Action: SpeCify the delayed display operation and resume address compare.
TO ALTER DATA, SPECIFY AN IMMEDIATE DISPLAY
Cause: You selected a display alter function. If you want to alter data, you must first display It.
Action:
None.
TO DELAY ALTER, ENTER NEW DATA, CHANGE I TO D, PRESS SEND
Cause: You selected the alter subfunctlon.
Action: As requested by the message.
UNKNOWN NCP COMPLETION CODE
Cause: The control program returned an unknown completion code after a mailbox was sent by the MOSS.
Action: Terminate the function
UNEXPECTED SCANNER INTERRUPT: PRESS SEND TO RETRY
Cause:
MOSS received a scanner interrupt on a command where no interrupt
IS
expected. A BER
IS
created: Type 01,10 OS.
Action:
Retry the command.
WARNING: lIC NOT ENABLED, DATA MAY BE ERRONEOUS
Cause: You want to display a control block (RAMA, RAMB, RAMe, leF, LIe, FPS, FLR, or LHR) when the LIe
IS In
disable 'status
(no line active).
Action:
None.
XX BYTES ALTERED
Cause: You specified an
Immediate alter operation
In
scanner/control storage, control blocks, local storage, or external regis-
ters. All displayed data, altered or not,
IS
transmitted to the scanner. "xx" corresponds to the size of the display,
not
to the
number of bytes you have altered.
Action:
None.