Procedure with MOSS Online
1. You must be in the CDF Display/update func-
tion (see page 9-15).
2. Display the CA (see "Display/Update Channel
Adapters" on page 9-19), then press F5.
3. This screen (m) is displayed.
4. Enter 3 in
D.
5. Press SEND.
• If the TPS is installed, screen
m
is dis-
played.
• If the TPS is not installed, screen
m
is
displayed.
If the CA number is even, only options 1 to 3 are
displayed.
1. Enter the selected mode in
D.
2. Press SEND.
3. Press F8 to update the other CA parameters
(screen
m).
• INTERFACE B information is displayed only if
TPS is installed.
• The ESC address range parameter is not
present if the CA is of type 7 (BCCA).
1. Update the desired fields, under INTERFACE
A, and INTERFACE B. (Refer to "CA Parame-
ters Explanation" on page 9-26 for details.)
2. Press SEND.
3. The following message is displayed:
UPDATE OF THE CDF FILE SUCCESSFUL
Display/Update CA
m
CuSTOMER lD:
3745
PROCESSW
",,-,,~"P.'Ifi·'~WIll""'Wl!lj
STOP-IOC-CHK STOP-CCU-CHK AC
SERIAL NUMBER:
CCU-A
RUN
MAXIMUM ADAPTERS CONFIGURATION: CHANNEL ADAPTERS
5, 6, 7, B
LINE
ADAPTERS
I,
3,
4, 9, IS, II, 12
-- -- --- -- -- - ---- ---- ------- ---- - -- ---- ------- - ---- ---- -------- -mm/dd/yy hh:mn
CDF - UPDATE : CA
xx
- SElECT ONE OPTION (1 TO 4), THEN PRESS SEND ==>
D
1 = DELETE CA
2
= REPLACE CA
3
0
UPDATE CA PARAMETERS
4 = ADO TWO PROCESSOR SWITCtt
IF CA TYPE 7 (BCCA): NO PEP SUPPORT, ANY PEP ACCESS LEADS TO A CP ABEND
USE NON-BUFFER CHAINING MODE IIITH NCP DOliN LEVEL_
F1
:END
F3:ALARf'.1
F6:QUIT
F7:DISPLAY
Figure
9-39. Update a CA (Menu Screen)
III
SIlITCH : --
IOC
: 1
CDF - DISPLAY/UPDATE: CA
xx
CAB
:--
GROUP :
x
PS ID : --
CCU
: A
ADDR :
xxxx
TYPE:
xxxx
SELECT TWO PROCESSOR SWITCH MODE
(TPS OR TCS) 0=>
D
- PRESS SEND
F1 :END
F3:ALARM
F6:QUIT
F7:DISPLAY
Figure
9-40. Update a CA
m
CDF - UPDATE : CA
xx
INTERFACE A
INTERFACE B
CHANNEL BURST LENGTH (4 TO 254)
==>
xxx
CHANNEL PRIORITY (L=LOII,H=HIGH)
==>
x
NSC ADDRESS (Oe TO FF)
==>
xx
DATA STREAMING (Y=YES,N=NO)
==>
x
HIGH SPEED DATA TRANSFER (Y=YES,N=NO)
==>
x
BYTE MULTIPLEXER CHANNEL (Y=YES.N=NO)
==>
x
DATA STREAMING SPEED (1 TO 3)
==>
x
(I=lMB. 2=2MB, 3=3MB)
ESC ADDRESS RANGE
(ee
TO FF)
==>
xx - xx
F1 :END
F3:ALARM
F6:QUIT
F7:BIID
Figure
9-41. Update a CA (Second Part)
Chapter 9. Configuration Data File (CDF)
9-23