IBM 3745 Service Functions page 212

Communication controller
Table of Contents

Advertisement

o
o
o
o
EXTEND NOT ACCEPTED
Cause:
The next MUX
IS
already attached.
Action:
Select the correct option without extend.
EXTEND PRESENCE MANDATORY, SELECT Y OR N
Cause:
The operator did not enter Y or N.
Action:
Retry with the correct Input (Y or N).
FUNCTION ALREADY PERFORMED
Cause:
DUring a hardware change, the same function was already performed.
Action:
None.
FUNCTION NOT SUPPORTED ON THIS MODEL
Cause:
Self-explanatory
Action:
None
INSTALL MODE NOT ESTABLISHED
CDF Messages
Cause:
DUring a CA hardware change, that CA
IS
attached, not Installed, and Install
IS
not in progress. The sequence of com-
mands was Invalid.
Action:
Restart a valid sequence of commands.
INVALID EXTEND PRESENCE, ENTER Y OR N
Cause:
DUring an LA hardware change, the operator did not enter Y (yes) or N (no).
Action:
Enter Y or N.
INVALID MUX NUMBER, ENTER 1 TO 32
Cause:
The operator has entered a MUX number which is not In the range from 1 to 32.
Action:
Retry With a correct value.
INVALID PORT RANGE
Cause:
The operator has entered a port range which
IS
not In the range from 0 to 1095.
Action:
Retry With a correct val ue.
LA IS ALWAYS PRESENT
Cause:
The operator has started a hardware change (DELETE LA), but that LA
IS
stili present.
Action:
Remove the proper LA.
LA IS NOT PRESENT
Cause:
After an
add or replace
LA, that LA
IS
not present.
Action:
Plug the proper LA In.
LA IS OPERATIVE
Cause:
The operator started a hardware change while the LA was operative.
Action:
Disconnect the LA through the TSS function.
MUX ATTACHED TO A L1C TYPE 5 OR 6 SHOULD BE ODD
Cause:
The MUX attached
IS
not In an odd position.
Action:
Install the MUX In a correct position.
MUX HAVE BEEN REPLACED
Cause:
The M UX has been replaced during a hardware change.
Action:
None.
MUX IS ALWAYS PRESENT
Cause:
After a DELETE MUX, that MUX
IS
stili present.
Action:
Remove the proper M UX.
MUX IS NOT PRESENT
Cause:
After an ADD or REPLACE MUX, that MUX
IS
not present.
Action:
Plug the proper MUX In.
MUX NUMBER MANDATORY, SELECT 1 TO 32
Cause:
The operator has entered a M UX number which
IS
not In the range from 1 to 32.
Action:
Retry With a correct value.
MUX NUMBER ATTACHED TO ANOTHER LA
Cause:
The operator has speCified a MUX number which already belongs to another LA.
Action:
Retry With a correct M UX number.