DIAG= =
>
The diagnostic group (1 to 8), 1FT, section, or routine that you want
to run (refer to the Diagnostic Descriptions SY33-2076, for details).
You may run a complete diagnostic group, an 1FT, a section of an 1FT
or a routine of a section of an 1FT, by entering:
• 1 through 8 to select all the diagnostics or a whole diagnostic
group (see "Diagnostic Request Menu Screen Description" on
page 3-13).
• The letter corresponding to a specific 1FT (for example P for the
FES 1FT Pl.
• The value corresponding to a specific section of an 1FT (for
example PA for section A of FES 1FT Pl.
• The value corresponding to a specific routine of a section of an
1FT (for example PA 10 for routine 10 of section A of FES 1FT Pl.
If you select an individual routine, you must previously run all pre-
ceding routines in sequence.
It is recommended to run the complete diagnostic group, otherwise
the results can be unpredictable.
ADP#= =
>
The adapter number:
• Channel number (5 to 8) for CA and OL T
• TSS number (3, 4, or 9 to 12)
• HPTSS number (3, 4)
• TRSS number (1).
LlNE= =
>
The number of a specific line (0 to 31) attached to a TSS or a spe-
cific line (1 to 2) attached to a TRSS. You must then specify the cor-
responding adapter number in the ADP# field.
OPT= =
>
Enter Y to display the diagnostic selection modify screen (see
Figure 3-5 on page 3-6) from which you may modify the options.
The default value is N (no modification).
The default running options are:
S
Stop on first error
NW
No wait before the execution of each routine
C1
Cycle
=
1
R1
Repeat each routine once
BR
BER recording
"Diagnostic Selection Modify Screen Description" on page 3-15 lists
all possible options, and how they can be modified.
"List and Duration of Diagnostics" on page 3-3 gives the list of all IFTs together
with their duration estimates.