Maximum; Minimum: Maximum; Cross Ref; Relevant For: Protection Level: Hla Data Type: Effective: Float Immediately - Siemens SINUMERIK 840D Description Of Functions

Hla module
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

02.99
5732
CL1_RES_IMAGE
Image ZK1_RES register
Unit:
Default:
HEX
0
Measuring circuit
limit frequency
reached
5609
ENC_SPEED_LIMIT
Max. measuring speed of linear scale
Unit:
Default:
mm/min
240 000.0
Velocity controller
at limit
5605
SPEEDCTRL_LIMIT_TIME
Time for velocity controller at limit
Unit:
Default:
ms
200.0
5606
SPEEDCTRL_LIMIT_THRESHOLD
Threshold for velocity controller at limit
Unit:
Default:
mm/min
120 000.0
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
Minimum:

Maximum:

0
FFFF
MD 5601: ALARM_MASK_RESET can be set to conceal Reset alarms. If the
relevant bit is set to 0, the corresponding error monitoring function is active. If
the bit=1, the relevant error message is suppressed. The default setting is "ac-
tive" for all monitoring functions.
MD 5613: ALARM_REACTION_RESET is set to configure switchover of the
relevant Reset alarm.
Alarm messages, see Chapter 6, numbers 300600...300699.
Minimum:
Maximum:
1.0
240 000.0
The limit frequency of the measured-value conditioning hardware is monitored
with respect to A/B signals. The limit frequency is calculated from machine data
MD 5005 and MD 5609. It is approximately 100 kHz and is normally specified
by the measuring system manufacturer.
Maximum measuring velocity (MD 5609) / increments (MD 5005) = encoder limit
frequency
Example: 120 000 mm/min / 20
Minimum:
Maximum:
20.0
1000.0
Minimum:
Maximum:
0.0
120 000.0
A message is activated if the manipulated voltage on the D/A converter is at the
limit continuously for a parameterizable time period and, at the same time, the
actual velocity is lower than a parameterizable threshold (MD 5606).
4 Firmware Drive Functions
4.13 Mounting functions
Relevant for:
HLA
Data type:
UNS.WORD
Relevant for:
HLA
Data type:
FLOAT
µ
m = 100 kHz
Relevant for:
HLA
Data type:
FLOAT
Relevant for:
HLA
Data type:
FLOAT
Cross ref.: –
Protection level:
3/3
Effective:
Immediately
Cross ref.: –
Protection level:
3/3
Effective:
Immediately
Cross ref.: –
Protection level:
3/3
Effective:
Immediately
Cross ref.: –
Protection level:
3/3
Effective:
Immediately
4-151