4 Firmware Drive Functions
4.7 Valve
4.7
Valve
Valve data
5106
VALVE_CODE
Valve code number
Unit:
Default:
–
0
5107
VALVE_NOMINAL_FLOW
Rate valve flow
Unit:
Default:
l/min
0.0
5108
VALVE_NOMINAL_PRESSURE
Rated valve pressure drop (per control edge)
Unit:
Default:
bar
35.0
5109
VALVE_NOMINAL_VOLTAGE
Rated valve voltage
Unit:
Default:
V
10.0
5110
VALVE_DUAL_GAIN_FLOW
Valve knee-point flow rate
Unit:
Default:
%
10.0
5111
VALVE_DUAL_GAIN_VOLTAGE
Valve knee-point voltage
Unit:
Default:
%
10.0
4-134
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
The rated valve data define the key valve data at the rated operating point. The
latter is defined by the
S
rated flow,
S
rated pressure drop and
S
rated voltage.
Minimum:
Maximum:
0
2000
Minimum:
Maximum:
0.0
1000
Minimum:
Maximum:
1.0
200.0
Minimum:
Maximum:
0.5
15.0
Valves with the associated data are included in the valve selection list (see Sec-
tion 2.3.2).
Other valve data are as follows:
S
Knee characteristic,
S
Flow ratio,
S
Dynamic definition with natural frequency and damping and
S
Valve configuration.
For a more detailed explanation of valves, see Section 2.3 and Appendix A.
Minimum:
Maximum:
0.2
95.0
Minimum:
Maximum:
0.2
95.0
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
UNS.WORD
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Siemens AG 2000. All rights reserved
08.99
02.99