02.99
4.11

Pressure sensors

Sensor adjustment
5550
PRESSURE_SENS_A_REF
Reference value of pressure sensor A at 10 V
bar
200.0
5552
PRESSURE_SENS_B_REF
Reference value of pressure sensor B at 10 V
200.0
Offset adjustment
5551
PRESSURE_SENS_A_OFFS
Offset adjustment for pressure sensor A
Unit:
Default:
-
0
5553
PRESSURE_SENS_B_OFFS
Offset adjustment for pressure sensor B
Unit:
Default:
-
0
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) - 04.00 Edition
Minimum:
50.0
400.0
50.0
400.0
The pressure at which the pressure sensor at the A and B cylinder ends outputs
10 V is entered in bar in MD 5550: PRESSURE_SENS_A_REF and MD 5552:
PRESSURE_SENS_B_REF.
The pressure sensor should have a range of 0 to 10 V, with 0 bar pressure rep-
resented by 0 V and the reference value (MD 5550 or. MD 5552) by 10 V.
Minimum:
Maximum:
-32760
32760
Minimum:
Maximum:
-32760
32760
The offset of the pressure sensor at the cylinder A and B ends is adjusted in
ADC increments in MD 5551: PRESSURE_SENS_A_OFFS and MD 5553:
PRESSURE_SENS_B_OFFS.
The pressure indicator should also display 0 bar at zero pressure. If the
velocity controller cycle is altered, the offset must be adjusted again.
Note
For automatic offset adjustment, see Section 3.9.2.