Static friction injection

Velocity threshold
5232
STICTION_SPEED_THRESHOLD
Velocity threshold for static friction
Unit:
Default:
mm/min
10.0
Cutoff limit
5233
STICTION_COMP_THRESHOLD
Cutoff limit static friction
Unit:
Default:
%
40.0
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
If a pressure sensor is installed and connected for the pressures at A and B, the
static friction injection function in MD 5241 can be activated.
Static force injection should not be activated if the cylinder must hold a varying
force of weight. In addition, the offset of the valve manipulated voltage and the
piston position must already have been adjusted. Machine data MD 5232...MD
5235 can be adjusted by means of a circularity test.
Velocity below which standstill and thus static friction is detected.
Minimum:
Maximum:
0.0
500.0
The force controller ensures that the force is limited to the value set in MD 5234
or MD 5235 when the velocity drops below the setting in MD 5232 for as long as
the drive is stationary.
Which of the two force setpoints is applied (MD 5234 or MD 5235) is determined
by the sign of the velocity setpoint.
The force controller is deactivated just before the setpoint is reached via the
cutoff limit (MD 5233) to prevent overshoots occurring during servo solenoid
valve actuation.
Minimum:
Maximum:
3.0
100.0
The force controller is deactivated just before the setpoint is reached via the
cutoff limit (MD 5233) to prevent overshoots occurring during servo solenoid
valve actuation.
If MD 5233 is set to 100%, then the force controller is not switched off until the
force setpoint (MD 5234 or MD 5235) is reached or unless the drive moves be-
forehand. This setting results in overshoots in the actual velocity value.
4 Firmware Drive Functions
4.4 Closed-loop force control
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
4-119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digital

Table of Contents